DESIGN DETAILS OF THE GROUND FLOOR
DESIGN DETAILS
OF THE GROUND FLOOR
1.
Shear walls
Width of the shear wall =230mm
Height of the shear wall = 3M
Concrete grade (fck) = 25N/mm2
Steel grade (fy) = 415N/mm2
2.
Buttresses
and pilaster
Width of the stem = 230m
Height of the stem = 3m
Bottom width = 2m
Depth of foundation = 0.45m
Width of the toe =
0.50 m
Width of the heel =
1m
Main reinforcement =
12mm dia @ 150mm c/c
Distribution reinforcement = 8mm dia @
200 mm c/c
Pilaster distance =
1800 mm
DESIGN DETAILS OF FIRST FLOOR
1. Vertical reinforcement = 12mm dia
bars @ 150mm c/c
2. Horizontal reinforcement = 8mm dia
bars @ 150mm c/c
3. Ring beam = 12mm dia
bars @ 230mm c/c
The reinforcements of
the first floor and roof of the ground floor will jointed and meet at roof
joints